SDM Series
SDM Series
Connect multiple modules to allow for simultaneous maintenance of several devices at a time, saving you time on testing and calibration. SDM-3R allows for connecting up to 10 modules at once.
Specifications
| Product Name | SDM-3R | SDM-6000 | ||
|---|---|---|---|---|
| Product Image |
|
|
||
| Product Subtitle | Calibration Station | Calibration Station | ||
| Product Type | Calibration Station | Calibration Station | ||
| Industries | Infrastructure, Sustainable Energy, Marine, Oil & Gas, Steel | Infrastructure, Sustainable Energy, Marine, Oil & Gas, Steel | ||
| Use Purpose | Calibration/Bump Testing | Calibration/Bump Testing | ||
| Single/Multi | ||||
| Certification | ||||
| Detectable Gas | N/A | N/A | ||
| Detection Range | N/A | N/A | ||
| Principle of Detection |
N/A | N/A | ||
| Sampling Method | Internal Sample Pump | Internal Sample Pump | ||
| Ingress Proof Rating |
N/A | N/A | ||
| Dimensions | Approx. 130 W x 100 H x 250 D mm (5.12" W x 3.94" H x 9.84" D) | Approx. 130 W x 330 H x 183 D mm (5.11" W x 13" H x 7.2" D) | ||
| Weight | Approx. 0.8 kg | Approx. 1.7 kg | ||
| Remarks | Charge, Calibrate, Bump Test, and Alarm Test | Charge, Calibrate, Bump Test, and Alarm Test | ||
| Power Source | 100 240 VAC | 100 240 VAC | ||
| Continuous Operation |
N/A | N/A | ||
| Operating Temperature Range |
0℃ to 40℃(no sudden changes) | 0℃ to 40℃ (No Sudden Changes) | ||
| Operating Humidity Range |
0 to 95 %RH (no-condensing) | 0 to 95 %RH (no-condensing) | ||
| Applicable Instruments |
GX-3R, GX-3R Pro | GX-6000 |
Expert Support Awaits – Get in Touch Today!
You may also be
interested in
Prevention from Explosions Inside Crushers @ Waste Facilities – Gas Detection System for Safe Workplace Environment
Gas detection systems prevent explosions in waste facility crushers by detecting combustible gases, ensuring worker safety, and maintaining operational stability through advanced technology and preventive strategies.
Protecting Workers from Oxygen Deficiency and Hydrogen Sulfide Poisoning. –– The “Dual Safety Measures” at Sewer Construction Sites.
Ensure worker safety in sewer construction with dual safety measures against oxygen deficiency and hydrogen sulfide poisoning. Learn about advanced gas detection solutions and protocols.
Why Redundancy is the Lifeline of Semiconductor Manufacturing? The “Dual-Backup” That Prevents Production Stop During Equipment Failures.
Discover how redundancy in semiconductor manufacturing, particularly through the FPM-80A gas detector, ensures continuous operation and mitigates costly production stops.
Why Customers Choose Us
Since our beginnings in 1939, Riken Keiki has continued to lead the way in gas detection technology, laying the foundations that support our modern society.
Discover why customers continue to choose Riken Keiki, the global standard in gas detection equipment.
See Our Solutions in Action!