GW-3 Series
GW-3 Series
Small yet highly durable.
IP66 and 68 rating
Drop test height: 2m
Explosion proofing: ATEX/IECEX certified
Three-step alarm
Quick & easy calibration
Data logger
Simultaneous display of gas concentration & time
Specification
| Product Name | GW-3(OX) | GW-3(HS) | GW-3(CO) | GW-3(C-) | GW-3(CX) |
|---|---|---|---|---|---|
| Product Image |
|
|
|
|
|
| Product Subtitle | Portable Gas Monitor | Portable Gas Monitor | Portable Gas Monitor | Portable Gas Monitor | Portable Gas Monitor |
| Product Type | Portable Gas Detector | Portable Gas Detector | Portable Gas Detector | Portable Gas Detector | Portable Gas Detector |
| Industries | Infrastructure, Sustainable Energy, Marine, Oil & Gas, Steel | Infrastructure, Sustainable Energy, Marine, Oil & Gas, Steel | Infrastructure, Sustainable Energy, Marine, Oil & Gas, Steel | Infrastructure, Sustainable Energy, Marine, Oil & Gas, Steel | Infrastructure, Sustainable Energy, Marine, Oil & Gas, Steel |
| Use Purpose | Safety management | Safety management | Safety management | Safety management | Safety management |
| Single/Multi | Single | Single | Single | Single | Multi |
| Certification | Japanese Certification, IECEx, ATEX, China Ex (China), JIS | Japanese Certification, IECEx, ATEX, China Ex (China), JIS | Japanese Certification, IECEx, ATEX, China Ex (China), JIS | Japanese Certification, IECEx, ATEX, China Ex (China), JIS | Japanese Certification, IECEx, ATEX, China Ex (China), JIS |
| Detectable Gas | O2 | H2S | CO | CO with H2 Elimination | CO & O2 Dual |
| Detection Range | 0.0 to 25.0 vol% | 0.0 to 100.0 ppm | 0 to 500 ppm | 0 to 500 ppm(0 to 2000 ppm) | 0 to 500 ppm (0 to 2000 ppm) (CO) 0.0 to 25.0vol% (0.0 to 40.0 vol%) (O2) |
| Principle of Detection |
Potentiostatic Electrolysis Method | Potentiostatic Electrolysis Method | Potentiostatic Electrolysis Method | Potentiostatic Electrolysis Method | Potentiostatic Electrolysis Method |
| Sampling Method | Diffusion | Diffusion | Diffusion | Diffusion | Diffusion |
| Ingress Proof Rating |
IP66/68 (2m, 1h) | IP66/68(2m, 1h) | IP66/68(2m, 1h) | IP66/68(2m, 1h) | IP66/68(2m, 1h) |
| Dimensions | Approx. 63 (W) x 42 (H) x 22 (D) mm (excluding projections) | Approx. 63(W)×42(H)×22(D) mm (excluding projections) | Approx. 63(W)×42(H)×22(D) mm (excluding projections) | Approx. 63(W)×42(H)×22(D) mm (excluding projections) | Approx. 63(W)×42(H)×22(D) mm (excluding projections) |
| Weight | Approx. 45g | Approx. 45 g | Approx. 45 g | Approx. 45 g | Approx. 45 g |
| Remarks | |||||
| Power Source | CR2450 Coin Type Lithium Ion Battery | CR2450 Coin Type Lithium Ion Battery | CR2450 Coin Type Lithium Ion Battery | CR2450 Coin Type Lithium Ion Battery | CR2450 Coin Type Lithium Ion Battery |
| Continuous Operation |
Approx. 2000 Hours | Approx. 4000 Hours | Approx. 4000 Hours | Approx. 2500 Hours | Approx. 2000 Hours |
| Operating Temperature Range |
-20 ℃ to +60 ℃ (no sudden changes) | -20 to +60℃ (no sudden changes) | -20 to +60℃ (no sudden changes) | -20 to +60℃ (no sudden changes) | -20 to +60℃ (no sudden changes) |
| Operating Humidity Range |
0 to 90 %RH (no condensation) | 0 to 95%RH (no condensation) | 0 to 95%RH (no condensation) | 0 to 95%RH (no condensation) | 0 to 95%RH (no condensation) |
| Applicable Instruments |
Expert Support Awaits – Get in Touch Today!
Related Industries
You may also be
interested in
Protecting Product Quality with Automated Air Intake Control
Outside air brought in through the plant’s air intake system can cause product quality issues. This article explains outside-air-related risks and introduces an approach using tape-type gas detection for high-sensitivity detection and automated control.
Safeguarding Next-Generation Ammonia Fuel Applications – Second-Level Calorific Value Control Technology for Unburned Gas Treatment
Explore innovative solutions for unburned ammonia treatment in co-firing power generation, emphasizing rapid calorific measurement technology and safety management.
Detecting Early Signs of Spontaneous Combustion with Gas Detection and Sampling Technology - A Biomass Power Plant Case Study in Silo Safety Management
Gas detection systems prevent explosions in waste facility crushers by detecting combustible gases, ensuring worker safety, and maintaining operational stability through advanced technology and preventive strategies.
How to Improve Quality Control Precision in the Mass Production of Organic Semiconductors: Introduction of Direct Energy-Level Evaluation
Gas detection systems prevent explosions in waste facility crushers by detecting combustible gases, ensuring worker safety, and maintaining operational stability through advanced technology and preventive strategies.
Why Customers Choose Us
Since our beginnings in 1939, Riken Keiki has continued to lead the way in gas detection technology, laying the foundations that support our modern society.
Discover why customers continue to choose Riken Keiki, the global standard in gas detection equipment.
See Our Solutions in Action!
See Our Solutions in Action!
Publications